<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Fandis &#8211; Elen Enclosures</title>
	<atom:link href="https://www.elen.co.za/brand/fandis/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.elen.co.za</link>
	<description>Electrical enclosures Distributors</description>
	<lastBuildDate>Tue, 05 Oct 2021 13:28:45 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2</generator>

<image>
	<url>https://www.elen.co.za/wp-content/uploads/2021/05/ELEN_logo_new_spaceman_right-100x100.png</url>
	<title>Fandis &#8211; Elen Enclosures</title>
	<link>https://www.elen.co.za</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Fandis TRT Thermostats</title>
		<link>https://www.elen.co.za/product/fandis-trt-thermostats/</link>
		
		<dc:creator><![CDATA[erez]]></dc:creator>
		<pubDate>Tue, 05 Oct 2021 13:05:29 +0000</pubDate>
				<guid isPermaLink="false">https://www.elen.co.za/?post_type=product&#038;p=1915</guid>

					<description><![CDATA[<strong>Thermostats</strong>

Single thermostats are used to control the temperature in an electrical enclosure, by operating a cooling or heating unit or signal device.

Available with Normally Open (NO), Normally Closed (NC), or change-over contact.

Normally Open: typically used to switch on a fan when internal temperature rises above the setpoint.

Normally Closed: typically used to switch off a heater when internal temperature rises above the setpoint.

Twin thermostats are used where multiple drives are required.

Integrates two independently operable devices into one compact assembly for simultaneously controlling heating, cooling or signaling devices via two knobs.

Setpoint adjustable from -10 <sup>o</sup>C - +80 <sup>o</sup>C

Mounting by a patented DIN rail clip-on system.

Screw terminal connection.

&#160;

<strong>Hygrostats</strong>

Hygrostats detect the level of humidity in the air inside the enclosure and operate the cooling or heating units when relative humidity exceeds the setpoint, to prevent condensation.

Setpoint adjustable from 0% - 90% RH

Mounting by a patented DIN rail clip-on system.

Screw terminal connection.]]></description>
										<content:encoded><![CDATA[<table style="height: 168px;" width="1123">
<tbody>
<tr>
<td width="148">NO / NC Thermostat</td>
<td width="136">Voltage</td>
<td width="100">Rated Current A</td>
<td width="102">Max Current A</td>
<td width="94">Setting Range</td>
</tr>
<tr>
<td width="148">TRT-10A230V-NC</td>
<td width="136">110-250 Vac; 60 Vdc</td>
<td width="100">10</td>
<td width="102">15</td>
<td width="94">-10… +80 °C</td>
</tr>
<tr>
<td width="148">TRT-10A230V-NO</td>
<td width="136">110-250 Vac; 60 Vdc</td>
<td width="100">10</td>
<td width="102">15</td>
<td width="94">-10+80 °C</td>
</tr>
</tbody>
</table>
<table style="height: 217px;" width="1122">
<tbody>
<tr>
<td width="148">Dual Thermostat</td>
<td width="136"></td>
<td width="100"></td>
<td width="102"></td>
<td width="94"></td>
</tr>
<tr>
<td width="148">TRT2-10A230V-NCNC</td>
<td width="136">110-250 Vac; 60 Vdc</td>
<td width="100">10</td>
<td width="102">15</td>
<td width="94">-10… +80 °C</td>
</tr>
<tr>
<td width="148">TRT2-10A230V-NCNO</td>
<td width="136">110-250 Vac; 60 Vdc</td>
<td width="100">10</td>
<td width="102">15</td>
<td width="94">-10… +80 °C</td>
</tr>
<tr>
<td width="148">TRT2-10A230V-NONO</td>
<td width="136">110-250 Vac; 60 Vdc</td>
<td width="100">10</td>
<td width="102">15</td>
<td width="94">-10… +80 °C</td>
</tr>
</tbody>
</table>
<table style="height: 145px;" width="1123">
<tbody>
<tr>
<td width="148">Change-over Thermostat</td>
<td width="136"></td>
<td width="100"></td>
<td width="102"></td>
<td width="94"></td>
</tr>
<tr>
<td width="148">TRT-230V-S01</td>
<td width="136">230 Vac</td>
<td width="100">Heat 10 / Cool 5</td>
<td width="102">10</td>
<td width="94">+5… +60 °C</td>
</tr>
</tbody>
</table>
<table style="height: 90px;" width="1125">
<tbody>
<tr>
<td width="148">Hygrostat</td>
<td width="136"></td>
<td width="100"></td>
<td width="102"></td>
<td width="94"></td>
</tr>
<tr>
<td width="148">IGR35F</td>
<td width="136">120-240 Vac</td>
<td width="100">5-Oct</td>
<td width="102"></td>
<td width="94">+10… +90 °C</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fandis FC Limit switches</title>
		<link>https://www.elen.co.za/product/fandis-fc-limit-switches/</link>
		
		<dc:creator><![CDATA[erez]]></dc:creator>
		<pubDate>Fri, 17 Sep 2021 06:32:26 +0000</pubDate>
				<guid isPermaLink="false">https://www.elen.co.za/?post_type=product&#038;p=1006</guid>

					<description><![CDATA[Used to switch off the voltage inside an enclosure or control other devices such as a lamp or fan.
Versions:
- Plain plunger (FC-001)
- Plain plunger with manual reset (FC-002)
- Roller plunger (FC-003)
- Roller plunger with adjustable lever (FC-004)
- Plain plunger with 3 NC contacts (FC-005)
For all versions: 1 Normally Open (NO) and 1 Normally Closed (NC) contact, except for FC-005 model with 3 Normally Closed (NC) contacts.

Accessories: Adjustable plastic support for easy positioning.]]></description>
										<content:encoded><![CDATA[<table style="height: 284px;" width="959">
<tbody>
<tr>
<td width="148">Limit Switch</td>
<td width="148">Type</td>
<td width="134">Voltage</td>
<td width="152">Rated Current A</td>
</tr>
<tr>
<td width="148">FC-001</td>
<td width="148">Plain plunger</td>
<td width="134">24-400 Vac; 24-250 Vdc</td>
<td width="152">6-0,4 A (dc); 10-4 A (ac)</td>
</tr>
<tr>
<td width="148">FC-002</td>
<td width="148">Plain plunger manual reset</td>
<td width="134">24-400 Vac; 24-250 Vdc</td>
<td width="152">6-0,4 A (dc); 10-4 A (ac)</td>
</tr>
<tr>
<td width="148">FC-003</td>
<td width="148">Roller plunger</td>
<td width="134">24-400 Vac; 24-250 Vdc</td>
<td width="152">6-0,4 A (dc); 10-4 A (ac)</td>
</tr>
<tr>
<td width="148">FC-004</td>
<td width="148">Roller plunger adjustable</td>
<td width="134">24-400 Vac; 24-250 Vdc</td>
<td width="152">6-0,4 A (dc); 10-4 A (ac)</td>
</tr>
<tr>
<td width="148">FC-005</td>
<td width="148">Plain plunger 3 NC contacts</td>
<td width="134">24-400 Vac; 24-250 Vdc</td>
<td width="152">6-0,4 A (dc); 10-4 A (ac)</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Orangis Thermal Control</title>
		<link>https://www.elen.co.za/product/orangis-thermal-control/</link>
		
		<dc:creator><![CDATA[davidw]]></dc:creator>
		<pubDate>Tue, 25 May 2021 14:54:01 +0000</pubDate>
				<guid isPermaLink="false">https://www.elen.co.za/?post_type=product&#038;p=197</guid>

					<description><![CDATA[<strong>Thermostats</strong>

Single thermostats are used to control the temperature in an electrical enclosure, by operating a cooling or heating unit or signal device.

Available with Normally Open (NO), Normally Closed (NC), or change-over contact.

Normally Open: typically used to switch on a fan when internal temperature rises above the setpoint.

Normally Closed: typically used to switch off a heater when internal temperature rises above the setpoint.

Twin thermostats are used where multiple drives are required.

Integrates two independently operable devices into one compact assembly for simultaneously controlling heating, cooling or signaling devices via two knobs.

Setpoint adjustable from -10 <sup>o</sup>C - +80 <sup>o</sup>C

Mounting by a patented DIN rail clip-on system.

Screw terminal connection.

&#160;

<strong>Hygrostats</strong>

Hygrostats detect the level of humidity in the air inside the enclosure and operate the cooling or heating units when relative humidity exceeds the setpoint, to prevent condensation.

Setpoint adjustable from 0% - 90% RH

Mounting by a patented DIN rail clip-on system.

Screw terminal connection.

&#160;]]></description>
										<content:encoded><![CDATA[<strong>Thermostats</strong>

Single thermostats are used to control the temperature in an electrical enclosure, by operating a cooling or heating unit or signal device.

Available with Normally Open (NO), Normally Closed (NC), or change-over contact.

Normally Open: typically used to switch on a fan when internal temperature rises above the setpoint.

Normally Closed: typically used to switch off a heater when internal temperature rises above the setpoint.

Twin thermostats are used where multiple drives are required.

Integrates two independently operable devices into one compact assembly for simultaneously controlling heating, cooling or signaling devices via two knobs.

Setpoint adjustable from -10 <sup>o</sup>C - +80 <sup>o</sup>C

Mounting by a patented DIN rail clip-on system.

Screw terminal connection.

&#160;

<strong>Hygrostats</strong>

Hygrostats detect the level of humidity in the air inside the enclosure and operate the cooling or heating units when relative humidity exceeds the setpoint, to prevent condensation.

Setpoint adjustable from 0% - 90% RH

Mounting by a patented DIN rail clip-on system.

Screw terminal connection.

&#160;]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Lumeis Enclosure Lamps</title>
		<link>https://www.elen.co.za/product/lumeis-enclosure-lamps/</link>
		
		<dc:creator><![CDATA[davidw]]></dc:creator>
		<pubDate>Tue, 25 May 2021 14:53:39 +0000</pubDate>
				<guid isPermaLink="false">https://www.elen.co.za/?post_type=product&#038;p=196</guid>

					<description><![CDATA[The CLG-L series of LED lamps are available with AC voltage 115 – 230Vac and ON/OFF switch.

Installation by means of metal brackets, designed for adjustable positioning and ease of use.

<strong> </strong>

<strong>Characteristics</strong>

Material: Casing in PC/ABS and diffuser in transparent polycarbonate.

Appliance Class: Class II

Power supply: 1.8m Cable

Protection: IP20

Storage temperature: -10°C to +70°C

Operating temperature: -0°C to +50°C

Lifetime at 40°C: 20,000h

Lumen Flux: 416 lm

LED Output: 7W

Ballast: Electronic incorporated

Switch: ON/OFF

Approvals: CE]]></description>
										<content:encoded><![CDATA[The CLG-L series of LED lamps are available with AC voltage 115 – 230Vac and ON/OFF switch.

Installation by means of metal brackets, designed for adjustable positioning and ease of use.

<strong> </strong>

<strong>Characteristics</strong>

Material: Casing in PC/ABS and diffuser in transparent polycarbonate.

Appliance Class: Class II

Power supply: 1.8m Cable

Protection: IP20

Storage temperature: -10°C to +70°C

Operating temperature: -0°C to +50°C

Lifetime at 40°C: 20,000h

Lumen Flux: 416 lm

LED Output: 7W

Ballast: Electronic incorporated

Switch: ON/OFF

Approvals: CE]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TCU Thermoelectric Coolers</title>
		<link>https://www.elen.co.za/product/tcu-thermoelectric-coolers/</link>
		
		<dc:creator><![CDATA[davidw]]></dc:creator>
		<pubDate>Tue, 25 May 2021 14:53:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.elen.co.za/?post_type=product&#038;p=195</guid>

					<description><![CDATA[FANDIS TCU Thermoelectric Coolers

Thermoelectric cooling units are small static heat pumps, which use the so-called “Peltier” effect.
Heat is transferred by a flow of electrical current through thermoelectric modules.
Heat is drawn from one side of the unit (the cold side) resulting in a temperature drop. The other side dissipates the heat into the surrounding environment (hot side).
The process can be reversed by simply inverting the direction of the current flow.

Thermoelectric cooling units are used to cool and dehumidify the air inside electrical cabinets and to separate the internal and exterior environments.

Advantages compared to a compressor system
Reliability: no moving mechanical parts (except fans, if applicable), have an almost unlimited life span and require no maintenance.
Static functioning: immune to vibration.
Installation flexibility: can be used in any position, and suitable for on systems in motion.
Environmentally friendly: contain no pollutants such as CFC or other harmful gases.
Compact: more compact structure than compressor systems.

DC thermoelectric units
• Solid-state device with Peltier technology
• Suitable for any plate thickness
• No chlorofluorocarbons (CFC) and compressor
• Reversible process heat/cool
• Operation in any orientation
• Not sensitive to vibration
• Virtually free maintenance - no moving parts (except for the fans)
Protection Rating: IP55]]></description>
										<content:encoded><![CDATA[<p>FANDIS TCU Thermoelectric Cooling Units</p>
<table style="height: 225px;" width="966">
<tbody>
<tr>
<td width="164">INSULATED PTC heaters</td>
<td width="84">Power</td>
<td width="76">Voltage</td>
<td width="113">Cooling Power W</td>
<td width="105">Rated Current A</td>
<td width="135">Drip Tray*</td>
</tr>
<tr>
<td width="164">TCU501240IP55</td>
<td width="84">5.0A</td>
<td width="76">12Vdc</td>
<td width="113">57</td>
<td width="105">5,8</td>
<td width="135">RC-TCU50-1001</td>
</tr>
<tr>
<td width="164">TCU502440IP55</td>
<td width="84">2.4A</td>
<td width="76">24Vdc</td>
<td width="113">57</td>
<td width="105">2,4</td>
<td width="135">RC-TCU50-1001</td>
</tr>
<tr>
<td width="164">TCU1002440IP55</td>
<td width="84">4.7A</td>
<td width="76">24Vdc</td>
<td width="113">101</td>
<td width="105">4,7</td>
<td width="135">RC-TCU100-1001</td>
</tr>
<tr>
<td width="164">TCU1004840IP55</td>
<td width="84">2.4A</td>
<td width="76">48Vdc</td>
<td width="113">101</td>
<td width="105">2,4</td>
<td width="135">RC-TCU100-1001</td>
</tr>
<tr>
<td width="164">TCU2002440IP55</td>
<td width="84">9.5A</td>
<td width="76">24Vdc</td>
<td width="113">201</td>
<td width="105">9,5</td>
<td width="135">RC-TCU200-1001</td>
</tr>
<tr>
<td width="164">TCU2004840IP55</td>
<td width="84">4.8A</td>
<td width="76">48Vdc</td>
<td width="113">201</td>
<td width="105">4,8</td>
<td width="135">RC-TCU200-1001</td>
</tr>
</tbody>
</table>
<p>*Drip tray recommended for humid installation environments where condensation may occur</p>
]]></content:encoded>
					
		
		
			</item>